Doepfer A-149-1 Quantized/Stored Random Voltages Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Audio Doepfer A-149-1 Quantized/Stored Random Voltages. Doepfer A-149-1 Quantized/Stored Random Voltages User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
doepfer
System A - 100
RCV
A-149 /1
1
1. Introduction
Module A-149-1 is a Random Control Voltage
Source based on the idea of Don Buchla's "Source of
Uncertainty 265/266" modules. It has available 4 ana-
log random voltages, that are generated in different
ways.
The Quantized Random Voltages section has avai-
lable the outputs N+1 and 2
N
States. N is an integer
number in the range 1...6 that can be adjusted manu-
ally (Man N) and by an external control voltage CVN.
The voltage steps are 1/12 V for the 2
N
output (i.e.
semitone intervals) and 1.0 V for the N+1 output (i.e.
octave intervals).
The
Stored Random Voltages
section has available
an output with
even voltage distribution with 256
possible output states and another output with
ad-
justable voltage distribution probability. The distri-
bution of this output can be adjusted manually (Man D)
and by an external control voltage CVD. The voltage
range is 0...+5 V for both stored random outputs.
The rising edge of the corresponding Clock input
signal triggers a new random voltage value at the
outputs.
Each output is equipped with a LED that displays the
current output voltage.
CV N In Man N
A-149
Clk In
RCV
n+1
CV N
Quantized RV
CV D In Man D
Clk In
CV D
Stored RV
2
n
Remark: The A-149-1 can be expanded by the A-149-2
module (8 digital random outputs with LED displays)
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - 1. Introduction

doepferSystem A - 100RCV A-149 /111. IntroductionModule A-149-1 is a Random Control VoltageSource based on the idea of Don Buchla's "So

Page 2 - 2. Overview

A-149 /1 RCVSystem A - 100doepfer22. OverviewControls and Indicators:1 Man N : manual control of “N”2 CV N : attenuator for CVN at input !3, 4

Page 3 - 3. Controls

doepferSystem A - 100RCV A-149 /133. Controls3.1 Quantized Random Voltages1 Man NThis is the manual control for the integer number N inthe range 1

Page 4 - D = 5 D ~ 10D ~ 0

A-149 /1 RCVSystem A - 100doepfer4Fig.1: Probability distribution for different settings of "D"H The final value of D is the sum of the

Page 5 - 5. User examples

doepferSystem A - 100RCV A-149 /154.2 Stored Random Voltages% CV D InThis socket is the Control Voltage input for theprobability distribution "

Page 6

A-149 /1 RCVSystem A - 100doepfer6tempo of the VCLFO A-147. Thus as the range of pitchselection increases the number of possible spectralranges bec

Commentaires sur ces manuels

Pas de commentaire